Ground-mounted photovoltaic systems need foundation components that suit the site soil, structural loads and mounting design. Baiyili, a professional manufacturer from China, supplies Ground Screw solutions for solar ground mounts, PV carports, fences and other outdoor structures, with dimensions and connection options selected for each project.
Installation works by rotating the helical steel pile into the ground, so the pile transfers structural loads into the surrounding soil. Anchor bolts and compatible mounting accessories complete the connection to the supported structure. Solar Roof Hook is a separate accessory for roof-mounted PV and is not normally part of a ground foundation assembly.


The table below lists supplied reference specifications. Final selection should follow the product drawing and project design.
| Item | Specification |
|---|---|
| Product Name | Ground Screw |
| Product Type | Helical ground screw / solar ground anchor |
| Main Material | Q235B / Q355B carbon steel |
| Surface Treatment | Hot-dip galvanized |
| Reference Zinc Coating Thickness | ≥85 μm, according to the supplied specification |
| Pipe Diameter | 76 mm / 89 mm / 114 mm / 140 mm, customizable |
| Pipe Wall Thickness | 2.0 mm / 2.5 mm / 3.0 mm / 3.5 mm / 4.0 mm |
| Pile Length | 1,000–3,000 mm, customizable |
| Helical Blade Diameter | 200–500 mm |
| Blade Quantity | 1, 2 or 3 blades, depending on the design |
| Top Connection | Flange plate, U-shaped connector or square head |
| Reference Uplift Capacity | 5–30 kN, depending on soil conditions, pile geometry and installation |
| Wind-Load Design | Project-specific; requires verification of the foundation, mounting structure, soil and site wind conditions |
| Reference Service Life | 25–30 years as supplied; actual durability depends on corrosion exposure, coating condition, installation and maintenance |
| Typical Applications | Ground-mounted PV, solar carports, fences and other suitable outdoor structures |
| Soil Compatibility | Determined by site investigation and installation assessment |
Load-capacity note: The stated uplift range is a reference, not a universal rating. Allowable capacity must be established for the selected pile and site conditions. Wind speed alone does not determine the capacity of the complete foundation system.
A Ground Screw is installed by rotating the pile into suitable soil with compatible installation equipment. This can reduce excavation and concrete-pouring work compared with conventional concrete foundations, depending on ground conditions and foundation design.
Shaft diameter, wall thickness, pile length, helical blade dimensions and top connection can be selected to match the proposed structure and site conditions.
The shaft and helical blades transfer loads from the supported structure into the surrounding soil. Compression, uplift and lateral resistance depend on soil properties, pile geometry, embedment depth and installation quality.
Hot-dip galvanizing provides a protective zinc coating for the steel components. Long-term performance depends on coating thickness, soil chemistry, moisture, exposure conditions and the treatment of damaged areas.
Where the installation method and soil conditions permit, a Ground Screw may be unscrewed and recovered when a project is dismantled. Reuse requires inspection of the shaft, blades, welds and coating.
Ground Screw configurations can be considered for ground-mounted PV, solar carports, fences and other structures with compatible loading and connection requirements. Site suitability must be established before installation.
| Component | Function |
|---|---|
| Steel Shaft | Forms the main body of the pile and transfers structural loads into the ground. |
| Helical Blade | Engages with the surrounding soil during installation and contributes to axial and lateral resistance. |
| Top Flange or Connection Plate | Provides an interface for connecting the pile to the supported mounting structure. |
| U-Shaped Connector or Square Head | Alternative connection forms for compatible mounting designs. |
Accessory compatibility depends on connection geometry, dimensions, load requirements and mounting design. These items should not be assumed to be universally interchangeable.
| Component | Material or Treatment | Selection Notes |
|---|---|---|
| Pile shaft and blades | Q235B or Q355B carbon steel | Material grade and section dimensions should match the specified design. |
| Corrosion protection | Hot-dip galvanizing | Coating thickness and coverage should meet the applicable specification. |
| Top flange or connection plate | Steel, according to the selected model | Connection dimensions and weld details should match the mounting structure. |
| Fasteners and related accessories | SUS304 stainless steel or other specified grades | Select materials according to joint requirements and environmental exposure. |
Ground Screw fabrication and inspection should address the following areas:
Salt-spray performance, load capacity and other test results should be supported by the corresponding product specifications and test records.
Start with the mounting layout, module arrangement, support spacing and design loads. Select pile diameter, length, blade geometry and top connection based on required load transfer and the site assessment.
Review the carport's column loads, overturning forces, wind exposure and foundation connection details. Pile dimensions and spacing should follow the structural design rather than the supported panel area alone.
Do not select a longer pile solely from a generic soil category. Soil density, groundwater, installation torque, blade dimensions and project loads all affect foundation performance. Site investigation or field testing may be necessary.
Check soil and environmental exposure when specifying the galvanizing system and fastener materials. For severe salt or corrosive conditions, assess coating requirements, material compatibility and the inspection and maintenance plan.
Evaluate the slope, soil profile, installation access and seasonal conditions before selecting the foundation. Frozen ground, rock, very loose soil and high groundwater may require specialized installation methods or another foundation solution.
Provide the site location, structural drawings, support spacing, soil information and applicable wind-design requirements. Verify the complete load path from the PV modules and mounting rails through the pile into the soil.
| Common Mistake | Correct Practice |
|---|---|
| Choosing a short pile without checking soil conditions | Use site investigation and the structural design to determine the required pile geometry and embedment. |
| Installing with unsuitable equipment or poor alignment | Use compatible rotary equipment and maintain the specified installation tolerance. |
| Selecting fasteners without checking material and connection requirements | Match the fastener grade, dimensions and tightening requirements to the joint specification. |
| Increasing pile spacing without approval | Follow the approved foundation layout and obtain engineering review before making changes. |
| Using an incompatible top connection | Check flange, connector and mounting-interface dimensions before installation. |
| Ignoring damage to the galvanized coating | Inspect damaged areas and apply an appropriate repair method according to the coating specification. |
| Installing without considering groundwater or difficult soil | Assess ground conditions and adapt the installation method or foundation design where necessary. |
Sea freight, land transportation and container shipment can be arranged according to order size and destination. Express shipment may suit small samples, depending on package dimensions and carrier requirements.
Reference lead times are 7–15 working days for standard Ground Screw models and 15–30 working days for customized piles or accessories. Confirm the current production schedule, order quantity and shipping arrangements before placing the order.
It can be an alternative for suitable ground-mounted applications, but not for every site. Soil conditions, structural loads, installation feasibility and required foundation capacity must be assessed.
No. Compatibility depends on connection dimensions and mounting design. Solar Roof Hook is generally used for roof-mounted PV, while this product provides a foundation for ground-mounted structures.
Service life depends on coating thickness, soil and salt exposure, moisture and maintenance. A long-term service-life claim should be supported by the specified coating and an environmental assessment.
Often, it can be unscrewed using suitable equipment. Reuse depends on whether the pile, welds, blades and corrosion protection remain in acceptable condition after removal.
Length should be determined from site investigation, required embedment, structural loads and installation conditions. Soil type alone is not sufficient to assign a universal pile length.
Normally, no. The pile is used for suitable ground foundations, while Solar Roof Hook is used for suitable roof-mounted PV systems.
Provide the required pile length, diameter, wall thickness, blade size and quantity, top connection, soil conditions, structural loads, coating requirements and delivery destination. Drawings or site information help determine a suitable pile configuration.
Address
Cai Gongzhuang Industrial Zone, Jinghai District, Tianjin, China
Tel
